henrik.lundin 0d8385770b NetEq: Convert AverageIAT from int to float calculations
With this change, the calculations inside AverageIAT are changed to be
in double-precision floating point instead of in fixed point. Also,
the method's name is changed to EstimatedClockDriftPpm to better
reflect what it returns.

A few unit tests had to be updated because of minor numerical
differences.

Also removing the UBSan suppression related to this issue.

BUG=webrtc:5889

Review-Url: https://codereview.webrtc.org/2408653002
Cr-Commit-Position: refs/heads/master@{#14628}
2016-10-13 10:35:58 +00:00
..
2016-05-10 12:54:43 +00:00
2016-04-26 14:45:26 +00:00
2014-06-09 08:10:28 +00:00